Assay Sensitivity Difference Can Induce Anti-Hepatitis A Virus IgM Non-Reactive But Total (IgM and IgG) Reactive Results in Early Acute Hepatitis A.

Ainda não traduzido Ainda não traduzido
Autores
Categoria Primary study
RevistaJournal of Korean medical science
Year 2022
Although anti-hepatitis A virus (HAV) IgM non-reactive and anti-HAV total (immunoglobulin [Ig] M and IgG) reactive results are generally interpreted as immunity to HAV, some early acute hepatitis A patients show the same results. We compared IgM detection sensitivity between anti-HAV IgM and anti-HAV total assays. Acute hepatitis A patients' samples were serially diluted and tested with Elecsys anti-HAV IgM and total assay (Roche Diagnostics). This resulted in anti-HAV IgM non-reactive but anti-HAV total reactive results. Samples of two hepatitis A patients showing false-negative anti-HAV IgM at initial presentation were analyzed with Elecsys, Atellica (Siemens Healthineers), and Alinity (Abbott Laboratories) HAV assays. Elecsys, Atellica, and Alinity anti-HAV IgM converted reactive on hospital day 3, whereas Elecsys and Atellica anti-HAV total results were reactive from hospital day 1. The anti-HAV total assay had higher sensitivity in detecting IgM antibodies than the anti-HAV IgM assay.
Epistemonikos ID: 994d5a8fc6dd013cb364cdcb41fffb566e561cb6
First added on: Nov 09, 2024