False positive Herpes Simplex IgM serology in COVID-19 patients correlates with SARS-CoV-2 IgM/IgG seropositivity.

Category Primary study
JournalDiagnostic microbiology and infectious disease
Year 2022
Differentiating COVID-19 from other causes of viral pneumonia, like herpes simplex (HSV), can be complicated by shared clinical and laboratory features. Viral pneumonia is mostly diagnosed based on molecular or serological techniques. Serological immunoassay interferences, often attributed to concurrent appearance of heterologous (viral) immunoglobulins, is well-known, but has not been studied in COVID-19 patients. Following false positive HSV immunoglobulin M (IgM) results in our index patient, 25 other COVID-19 patients were tested for HSV-1/2 IgM with the chemiluminescent Liaison assay and Euroimmun enzyme-linked immunosorbent assay. Forty-five percent of COVID-19 patients tested positive for HSV IgM with Liaison. No HSV indices were positive with Euroimmun enzyme-linked immunosorbent assay, suggesting immunoassay interference. Significant correlation between HSV IgM and SARS-CoV-2 IgM/IgG positivity was found. Adding 0.5% polyvinylpyrrolidone, inhibiting non-specific solid-phase adsorption, abolished interference in 22% of false positive cases, suggesting interference caused by solid-phase reactive IgM. Hence, serologic immunoassay results should be interpreted with caution in COVID-19 patients.
Epistemonikos ID: ebda18349bc3ffcfcb8674622670544fda335058
First added on: Mar 03, 2022