Diagnostic criteria for scrub typhus: probability values for immunofluorescent antibody and Proteus OXK agglutinin titers.

Authors
Category Primary study
JournalThe American journal of tropical medicine and hygiene
Year 1983
The sensitivities and specificities of the indirect microimmunofluorescent antibody (IFA) and Weil-Felix (OXK) tests for scrub typhus were established for a range of titers using groups of diseased and control (other febrile illnesses) patients diagnosed by other methods. At a cut-off point of greater than or equal to 1:400, the IFA test was 0.96 specific, and at greater than or equal to 1:320, the OXK was 0.97 specific. Using either these highly specific levels of antibody or other rigorous diagnostic criteria (isolation or 4-fold rising titers), the prevalence of scrub typhus infection was determined to be 0.22 in an unselected population of febrile patients in a rural Malaysian hospital. Probability values (Pr) for the correct diagnosis of scrub typhus were then calculated from the specificity, sensitivity and prevalence determination for a range of titers. The Pr for an OXK titer of greater than or equal to 1:320 was 0.79, and the Pr for an IFA titer of greater than or equal to 1:400 was 0.78. When both these titers were present in a single specimen, the Pr increased to 0.96.
Epistemonikos ID: e9b878d9cc3ca97e8ad0a4e967e9c598ebbe20ea
First added on: Nov 11, 2024