Influence of Implantation Technique on Rotational Stability of a Frosted-Haptic Toric Intraocular Lens: A Prospective Contralateral-Eye Study

Authors
Category Primary study
Registry of TrialsClinicalTrials.gov
Year 2026
This prospective, randomized contralateral-eye study evaluates whether the implantation technique influences the rotational stability and refractive outcomes of the TECNIS Eyhance™ Toric II intraocular lens (IOL) during cataract surgery. Although balanced salt solution (BSS) hydroimplantation has been proposed to reduce postoperative IOL rotation by eliminating retained ophthalmic viscosurgical device (OVD), the effect of implantation technique on the rotational stability of modern frosted-haptic toric IOLs remains uncertain. Patients undergoing bilateral cataract surgery with regular corneal astigmatism receive TECNIS Eyhance™ Toric II IOLs in both eyes. One eye is randomized to OVD-assisted implantation and the fellow eye to BSS-assisted hydroimplantation. The primary outcome is postoperative rotational stability assessed using OPD-Scan III at postoperative day 1, week 1, and month 1. Secondary outcomes include postoperative refractive astigmatism, astigmatic prediction error, and visual acuity. The study aims to determine whether implantation technique influences postoperative rotational stability or refractive performance when using a contemporary frosted-haptic toric IOL.
Epistemonikos ID: d0ea4a66c8e78ff27fd81b1dc0e46ee1d54d56f2
First added on: Aug 17, 2026