Adhesion formation after laparoscopic ventral incisional hernia repair with polypropylene mesh: a study using abdominal ultrasound.

Category Primary study
JournalJSLS : Journal of the Society of Laparoendoscopic Surgeons
Year 2004
OBJECTIVE: Laparoscopic repair of ventral incisional hernias is feasible and safe. Polypropylene mesh is often preferred because of its ease of handling and lower cost. Complications like adhesion and fistula formation can occur. The goal of this study was to determine whether bowel adhesions and their attendant complications could be prevented by interposition of omentum. METHODS: Thirty patients underwent laparoscopic ventral incisional hernias repair with polypropylene mesh. Omentum was always positioned over the loops of bowel for protection. At a mean follow-up of 14 months, 20 patients underwent ultrasonic examination using the previously described visceral slide technique to detect adhesions. RESULTS: The mean size of the hernias in the study was 50.3 cm2, and the mean size of the mesh applied was 275 cm2. Thirteen patents (65%) had no sonographically detectable adhesions. Five patients demonstrated adhesions between the mesh and omentum, 1 patient developed adhesions between the left lobe of the liver and the mesh, and only 1 case of bowel adhesion to the edge of the mesh was found. CONCLUSION: Laparoscopic ventral incisional hernias repair with polypropylene mesh and omental interposition is not associated with visceral adhesions in the majority of patients. Polypropylene mesh can be used safely when adequate omental coverage is available.
Epistemonikos ID: c6fc3373f16cf9c2247d3bbc6f650633e43f02c1
First added on: Jul 24, 2018