Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials.

Authors
Category Systematic review
JournalDiabetes research and clinical practice
Year 2026
We evaluated whether closed-loop insulin delivery improves glycaemic control in hospitalised and perioperative adults. PubMed/MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched from inception to 29 June 2026 for randomised controlled trials comparing closed-loop or automated insulin delivery with usual care or conventional insulin therapy. Random-effects meta-analyses were conducted; risk of bias was assessed using RoB 2 and certainty of evidence using GRADE. Seven trials involving 375 analysed participants were included. Closed-loop insulin delivery increased time in target glucose range by 23.91 percentage points (95% CI 19.40 to 28.43; I2 = 0%) and reduced mean glucose by 1.79 mmol/L (95% CI 1.06 to 2.53 lower; I2 = 36.3%); certainty was moderate for both outcomes. Two trials involving 69 participants reported compatible participant-level data for clinically significant hyperglycaemia, and both estimates favoured closed-loop insulin delivery, although the evidence was exploratory and imprecise. No severe hypoglycaemic events occurred in either group, precluding reliable estimation of comparative safety. Closed-loop insulin delivery may improve glycaemic process measures, but larger pragmatic trials are needed to establish clinical benefits, safety, and implementation feasibility. © 2026 Elsevier B.V.
Epistemonikos ID: 911f658e7b7dd1e15344efe2aa119fef19960f64
First added on: Aug 26, 2026