Effects of electroacupuncture on hepatic blood flow and lipid peroxidation in septic rats

Authors
Category Primary study
JournalZhongguo zhen jiu = Chinese acupuncture & moxibustion
Year 2010
OBJECTIVE: To investigate the protection effects of electroacupuncture on injury of lipid peroxidation induced by liver ischemia in septic rats. METHODS: Forty-eight male SD rats were subjected to sepsis induced by cecal ligation and puncture (CLP), and were randomly divided into a Sham operation group (group A), a CLP model group (group B), a CLP model plus electroacupuncture at "Zusanli" (ST 36) group (group C), a CLP model plus electroacupuncture at the shame acupoint (group D), a vagotomy plus CLP model group (group E) and CLP model plus electroacupuncture group after vagotomy (group F), 8 rats in each group. CLP was performed in group E and group F after the abdominal vagotomy. Bilateral "Zusanli"(ST 36) points and the shame acupoint were electroacupunctured (2 mA, 2/100 Hz) for 1 hour in group C, group F and group D, respectively. The hepatic blood flow (HBF) was detected by a laser-Doppler flowmetry at 6 h after CLP. The plasma activity of alanine aminotransferase (ALT) was also determined and specimens of liver were harvested for evaluation of malondialdehyde (MDA), xanthine oxidase (XOD) and assessment of the rate of water content. RESULTS: The blood flow of the liver was (56.97 +/- 11.95) U in group C which was significantly lower than (80.12 +/- 19.57) U in group A but higher than (42.61 +/- 10.97) U in group B, (44.53 +/- 9.23) U in group D, (30.05 +/- 4.46) U in group E and (30.46 +/- 6.38) U in group F (all P < 0.05) 6 h after CLP. Meanwhile, the levels of MDA, XOD, ALT and the rates of water content in liver in group C were all significantly higher than those in group A, but lower than those in the other four groups (all P < 0.05). The levels of MDA, XOD, ALT and the rates of water content in liver in group E and group F were all significantly higher than those in group D (all P < 0.05), while the blood flow of the liver lower than that in group D (P < 0.05), and with no significant differences in all above measurements between group E and group F (all P > 0. 05). CONCLUSION: Electroacupuncture at "Zusanli" (ST 36) can promote hepatic blood flow, inhibit lipid peroxidation and alleviate hepatic edema and dysfunction in septic rats, which might be related with the completeness of cranial nerve.
Epistemonikos ID: 789959319a59705576989ffcb434e1a3915add4e
First added on: Jun 14, 2020