Authors
»
李萍 -More
Category
»
Primary study
Year
»
2020
Objective: To analyze the clinical value of serum 2019 novel coronavirus (2019-NCoV) immunoglobulin M (IgM) and immunoglobulin G (IgG) antibodies in diagnosing novel coronavirus pneumonia (NCP). Method: Case control study. Collected from January to February 2020 at the First Affiliated Hospital of Hunan University of Chinese Medicine and the First Hospital of Xiamen University A total of 116 confirmed patients in the disease group, the non-NCP population contained 84 patients and 50 health examiners, a total of 134 cases in the control group. Collect serum specimens from all study subjects. A fully automated chemoluminescent immunoanalyzer detects 2019-NCoV IgM and IgG antibody concentrations in serum. The sensitivity and specificity of 2019-NCoV IgM, IgG antibody monomial test and its combined detection were compared using the ≈ 2 test, and the comparison of IgM, IgG antibody positivity and concentration before and after NCP patients 2019-NCoV nucleic acid transpubic acid, respectively. The trend of change in concentration of 2019-NCoV antibodies in patients with NCP is used by Wilcoxon rank and test. Results: The sensitivity of 2019-NCoV IgG (90.5%, 105/116) was higher than 2019-NCoV IgM (75.9%, 88/116), the difference was statistically significant (≈ 2=8.91, P<0.05); the specificity of 2019-NCoV IgG (99.3%, 133/134) was higher than 2019- NCoV IgM (94.0%, 126/134), the difference is statistically significant (2=5.63, P<0.05). The sensitivity after 2019-NCoV IgM combined IgG (89.7%, 87/97) is higher than 2019-NCoV IgM, the difference is statistically significant (≈ 2=6.89, P<0.05); the specificity after 2019-NCoV IgG (100%, 125/125) is higher than 2019-NCoV IgM, The difference is statistically significant (≈ 2=7.70, P<0.05). Serum 2019-NCoV IgM antibody positive rate (9/17) and concentration [13.0 (4.9, 24.7) AU/mL] after 2019-NCoV nucleic acid transpubic acid transpubic positive rate (15/17) and concentration [29.5 (14.0, 61.3) AU/mL] (≈ 2=5.10, Z=- 3.195, P both <0.05). In the course of NCP, the patient serum specimen is retained from day 1 of diagnosis to three days at intervals. 1st 2019-NCoV IgM and IgG antibody concentrations [19.4 (12.4, 63.7) AU/mL, 105.8 (74.8, 126.1) AU/mL, respectively] were both significantly higher than the 2nd concentration [15.8 (7.1, 40.3) AU/mL, 80.5 (66.7, 105.9) AU/mL, respectively] (Z 2.897, -3.179, P both <0.05). Conclusion: 2019-NCoV IgG antibodies have good application value for diagnosing NCP; 2019-NCoV IgM antibody concentration has some association with 2019-NCoV nucleic acid detection; 2019-NCoV IgM and IgG antibodies combined with 2019-NCoV nucleic acid detection may be the best laboratory indicator for diagnosing NCP at present.
This translation has been produced by an automated software. If you wish to submit your own translation, please send it to translations@epistemonikos.org
Epistemonikos ID: 5affa7cf2750add2dc862d0f66dbe97365870657
First added on: Aug 14, 2020