Cervical disc prosthesis replacement and interbody fusion: a comparative study.

Authors
Category Primary study
JournalInternational orthopaedics
Year 2008
The purpose of this paper is to compare the new functional intervertebral cervical disc prosthesis replacement and the classical interbody fusion operation, including the clinical effect and maintenance of the stability and segmental motion of cervical vertebrae. Twenty-four patients with single C5-6 intervertebral disk hernias were specifically selected and divided randomly into two groups: One group underwent artificial cervical disc replacement and the other group received interbody fusion. All patients were followed up and evaluated. The operation time for the single disc replacement was (130 +/- 50) minutes and interbody fusion was (105 +/- 53) minutes. Neurological or vascular complications were not observed during or after operation. There was no prosthesis subsidence or extrusion. The JOA score of the group with prosthesis replacement increased from an average of 8.6 to 15.8. The JOA score of the group with interbody fusion increased from an average of 9 to 16.2. The clinical effect and the ROM of the adjacent space of the two groups showed no statistical difference. The short follow-up time does not support the advantage of the cervical disc prosthesis. The clinical effect and the maintenance of the function of the motion of the intervertebral space are no better than the interbody fusion. At least 5 years of follow-up is needed to assess the long-term functionality of the prosthesis and the influence on adjacent levels.
Epistemonikos ID: 4934f63dc9176214b2fa93953f86a2e6caa33ab2
First added on: Dec 26, 2019