Measurement of urinary vanilmandelic acid and homovanillic acid by high-performance liquid chromatography with electrochemical detection following extraction by ion-exchange and ion-moderated partition.

Authors
Category Primary study
JournalJournal of chromatography
Year 1984
An improved protocol has been developed to isolate homovanillic acid (HVA) and vanilmandelic acid (VMA) from urine with strong anion-exchange resin. The sample is diluted with acetate buffer and passed through a disposable column. HVA, uric acid, and many hydrophobic organic acids are removed with 1.0 M acetic acid--ethanol. Then VMA is eluted with 0.5 M phosphoric acid. Two isocratic mobile phases allow rapid high-performance liquid chromatographic measurement of VMA (5 min) and HVA (8 mins) on a 5-micron ODS column. Selective conditions were developed with dual-electrode coulometric detection to permit specific measurement of VMA, HVA, and internal standards, with less than 5% between-run variation.
Epistemonikos ID: 3dd038dab75c26b6750b1bc78855500527861041