Do repeat 6-minute walk tests provide clinically meaningful information in symptomatic heart failure?

Authors
Category Primary study
JournalESC Heart Fail.
Year 2026
Background and Aims: Two baseline 6-minute walk tests (6MWTs) have been recommended to mitigate a potential learning effect when assessing exercise performance, but the magnitude of any learning effect in heart failure with reduced ejection fraction (HFrEF) is uncertain. Using the Sildenafil in Heart Failure (SilHF) trial, in which two baseline 6MWTs were performed (screening and inclusion), we assessed a potential learning effect in this population. We also assessed whether choice of baseline test affected associations with longitudinal patient-reported outcomes and compared our findings to reports in the current literature. Methods: In SilHF, 69 patients with HFrEF and evidence of pulmonary hypertension performed 6MWTs at screening and again at study inclusion. Tests were performed no more than 2 weeks apart on unchanged optimal medical therapy. Only the inclusion 6MWT was used for efficacy evaluation of sildenafil. Screening and inclusion distances were compared using a paired t-test. Additionally, we assessed whether each baseline 6MWT (screening and inclusion) correlated with longitudinal patient-reported outcome measures. Outcomes included the Kansas City Cardiomyopathy Questionnaire and the EuroQoL-5D visual analogue scale, assessed at 24 weeks. Results: Although the inclusion 6MWT distance was statistically significantly higher than the screening test (+11.3 m, 95% confidence interval 2.6–20.1, P = .012), the two baseline tests demonstrated very similar correlation coefficients with longitudinal patient-reported outcomes. Conclusion: We observed a small increase in 6MWD between repeat baseline tests, consistent with a modest learning effect that is unlikely to be clinically meaningful. Both initial 6MWTs showed similar significant correlations with other longitudinal patient-reported outcome measures. In symptomatic HFrEF with pulmonary hypertension, a single baseline 6MWT may be sufficient to assess functional capacity. © The Author(s) 2026. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
Epistemonikos ID: 32fe7e5f096faeab1f6baf5de330334c78722b9d
First added on: Oct 17, 2026