Chest Compression Quality in a Newborn Manikin: A Randomized Crossover Trial (August 2016)

Category Primary study
JournalIEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE
Year 2018
The objective of this paper was to examine the changes in applied force and rate of chest compression (CC) during 5 min of CC with a target CC rate of 90/min (CC90) or 120/min (CC120) with and without metronome guidance during simulated neonatal cardiopulmonary resuscitation (CPR). We performed a randomized controlled manikin trial. Fourteen neonatal resuscitation program providers performed CC90 and CC120 with or without a metronome in a randomized order. Peak and residual leaning force and CC rate each minute of CPR were analyzed with Friedman's analysis of variance (ANOVA) (within interventions) and two-way repeated measures ANOVA (between interventions). There was a large variability in force application, with no difference between groups. Peak and residual leaning forces in CC90 and CC120 did not change with time with or without a metronome. The CC rate increased with time in all groups except CC90 without a metronome. In conclusion, neither the target CC rate nor using a metronome influenced the peak and residual leaning forces during simulated neonatal CPR.
Epistemonikos ID: 14d02e34771f9a6f1c69439ad5f9451417cbd443
First added on: Sep 05, 2023